Browse Categories

Search in Category

Filter Paper

Search Filters

  • GLASS x

Browse Categories

Loading...

Filter Paper

Supplies/Filter Paper 
Viewing Page 1 of 3 (23 results)

GD120 Filter, Glass Fiber, 125mm

Item #: MFS/GD120125MM
Supplier #: GD120125MM

Pack of 50
UOM : PK


Add to Quote

GA55 Filters, Glass Fiber, 125mm

Item #: MFS/GA55125MM
Supplier #: GA55125MM

Pack of 100
UOM : PK


Add to Quote

Filter Glass Fiber 55mm

Item #: MFS/GA5555MM
Supplier #: GA5555MM

Advantec MFS Inc.
Mfg Item # : GA5555MM
Advantec Glass Fiber Depth Filters feature high-loading capacity, fast flow rates, are highly resistant to chemical attack, and biologically inert. General purpose and clarifying filtration grades. Binder-free and thermostable to 500°C. Grade GA55 is a thin filter recommended for clarifying filtration and air pollution monitoring. Nominal Rating 0.6µm Grade GF75 collects very fine particles and has a high collection efficiency at 99.999%(DOP) and slower flow. Ideal for collecting IgG or other very fine protein precipitates. Use for TCLP EPA 1311. Nominal Rating 0.3µm(0.7µm) Grade GB140 is a thick filter with a high loading capacity. Used in industrial waste analysis and for suspended solids. Nominal Rating 0.4µm Grade GC50 is a thin filter recommended as a prefilter for membrane or suspended solids and pollutants in water. Low absorption makes this an ideal filter for scintillation counting. High Collection Efficiency(DOP) of 99.99%. Nominal Rating 0.5µm Grade GD120 has high wet strength and high-loading capacity. Ideal as prefilter for membrane <1.2µm. Nominal Rating 0.9µm Please Note: ALL Advantec items have a maximum 48 hour cancellation window. Any cancellations AFTER the 48 hour window will incur a restocking fee equal to the cost of the product.
UOM : EA


Add to Quote
Glass Fiber Filters GA55 90mm

Glass Fiber Filters GA55 90mm

Item #: MFS/GA5590MM
Supplier #: GA5590MM

Advantec MFS Inc.
Mfg Item # : GA5590MM
Advantec Glass Fiber Depth Filters feature high-loading capacity, fast flow rates, are highly resistant to chemical attack, and biologically inert. General purpose and clarifying filtration grades. Binder-free and thermostable to 500°C. Grade GA55 is a thin filter recommended for clarifying filtration and air pollution monitoring. Nominal Rating 0.6µm Grade GF75 collects very fine particles and has a high collection efficiency at 99.999%(DOP) and slower flow. Ideal for collecting IgG or other very fine protein precipitates. Use for TCLP EPA 1311. Nominal Rating 0.3µm(0.7µm) Grade GB140 is a thick filter with a high loading capacity. Used in industrial waste analysis and for suspended solids. Nominal Rating 0.4µm Grade GC50 is a thin filter recommended as a prefilter for membrane or suspended solids and pollutants in water. Low absorption makes this an ideal filter for scintillation counting. High Collection Efficiency(DOP) of 99.99%. Nominal Rating 0.5µm Grade GD120 has high wet strength and high-loading capacity. Ideal as prefilter for membrane <1.2µm. Nominal Rating 0.9µm Please Note: ALL Advantec items have a maximum 48 hour cancellation window. Any cancellations AFTER the 48 hour window will incur a restocking fee equal to the cost of the product.
UOM : PK


Add to Quote

GD120 Filters, Glass Fiber 150mm

Item #: MFS/GD120150MM
Supplier #: GD120150MM

Pack of 50
UOM : PK


Add to Quote
TCLP Glass Fiber Filters 47mm

TCLP Glass Fiber Filters 47mm

Item #: FIS/09-804-142H

Binder-free, borosilicate glass fiber filters have 0.7 micron pore size · 47mm size recommended for use with 09-753-1A Filter Holder in filtering highly granular samples or those with <10% solids · 90mm size recommended for use with 09-753-2.
UOM : PK


Add to Quote

Microfiltration Assy 47mm Ultra-Ware™

Item #: KTS/953750-5347
Supplier #: 953750-5347

Filtration Microfiltration Assembly 47 mm with Bottle and Fritted Glass Support Ultra-Ware 47 mm Filtration Assembly with Bottle and Fritted Glass Support This filtration assembly is specially designed to collect the filtrate directly into a media-style bottle. Exact Match KT953750-5347
UOM : CS


Add to Quote
Filter Glass 0.5M 25MM PK 100

Filter Glass 0.5M 25MM PK 100

Item #: TMS/4749A04
Supplier #: 4749A04

GVS Filter Technology Part No. 1215544
Extend the life of final filters Pore sizes from 0.5 µm to 1.0 µm With or without binders Autoclavable PreSep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Frequency and cost of replacing the final membrane filters is reduced. Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. Maximum operating temperature is 165°C (325°F). Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Not recommended for temperatures exceeding 510°C (950°F). For upstream protection of a membrane within a filter holder, the use of a prefilter that is slightly smaller in diameter than the main filter allows the prefilter to fit inside the O-ring or filter funnel holder seal, ensuring a positive membrane seal. When used as the main filter medium, select a diameter of the same size as the filter holder to be used. Type G15 Glass Fiber Prefilters with Binders (4749A02 to A14) Nominal pore size- 0.5 µm High rentention efficiency Limited dirt-handling capacity Protection of 0.2 µm to 0.8 µm final filters Type G20 Glass Fiber Prefilters with Binders (4749A20 to A32) Nominal pore size- 1.0 µm Surface capture of particles Average retention efficiency Higher dirt-handling capacity Protection of 0.8 µm and larger pore size final filters Type G25 Glass Fiber Prefilters with Binders (4749A40 to A54) Nominal pore size- 1.0 µm Thickness approximately 3.5 times greater than G20 Depth particle capture Average retention efficiency Highest dirt-handling capacity Recommended for solutions with heavy contaminate loads Protection of 0.8 µm and larger pore size final filters Type G40 Glass Fiber Prefilters WITHOUT Binders (4638D60 to D68) Nominal pore size- 1.0 µm Average retention efficiency Highest dirt-handling capacity Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents TCLP Glass Fiber Filters WITHOUT Binders, 0.7 µm Pore Size (4749A72) Borosilicate glass fiber filters designed for use in U.S. EPA Method 1311 Toxicity Characteristic Leaching Procedure (TCLP). Federal regulations require the filters for this application be made of borosilicate glass fiber, contain no binder materials and have an effective pore size of 0.6 to 0.8 microns. GE TCLP glass fiber filters have a pore size of 0.7 microns and are binder free. They are used in Zero-Headspace Extractor Vessels for determining the mobility of semi-volatiles. Filters should be acid washed prior to use with 1N nitric acid followed by three consecutive rinses with deionized water. A minimum of 1 liter per rinse is recommended.
UOM : PK


Add to Quote
Glass Fiber Filter 0.7um 47mm pack/100

Glass Fiber Filter 0.7um 47mm pack/100

Item #: TMS/4749A72
Supplier #: 4749A72

GVS Filter Technology Part No. 1215540
Extend the life of final filters Pore sizes from 0.5 µm to 1.0 µm With or without binders Autoclavable PreSep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Frequency and cost of replacing the final membrane filters is reduced. Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. Maximum operating temperature is 165°C (325°F). Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Not recommended for temperatures exceeding 510°C (950°F). For upstream protection of a membrane within a filter holder, the use of a prefilter that is slightly smaller in diameter than the main filter allows the prefilter to fit inside the O-ring or filter funnel holder seal, ensuring a positive membrane seal. When used as the main filter medium, select a diameter of the same size as the filter holder to be used. Type G15 Glass Fiber Prefilters with Binders (4749A02 to A14) Nominal pore size- 0.5 µm High rentention efficiency Limited dirt-handling capacity Protection of 0.2 µm to 0.8 µm final filters Type G20 Glass Fiber Prefilters with Binders (4749A20 to A32) Nominal pore size- 1.0 µm Surface capture of particles Average retention efficiency Higher dirt-handling capacity Protection of 0.8 µm and larger pore size final filters Type G25 Glass Fiber Prefilters with Binders (4749A40 to A54) Nominal pore size- 1.0 µm Thickness approximately 3.5 times greater than G20 Depth particle capture Average retention efficiency Highest dirt-handling capacity Recommended for solutions with heavy contaminate loads Protection of 0.8 µm and larger pore size final filters Type G40 Glass Fiber Prefilters WITHOUT Binders (4638D60 to D68) Nominal pore size- 1.0 µm Average retention efficiency Highest dirt-handling capacity Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents TCLP Glass Fiber Filters WITHOUT Binders, 0.7 µm Pore Size (4749A72) Borosilicate glass fiber filters designed for use in U.S. EPA Method 1311 Toxicity Characteristic Leaching Procedure (TCLP). Federal regulations require the filters for this application be made of borosilicate glass fiber, contain no binder materials and have an effective pore size of 0.6 to 0.8 microns. GE TCLP glass fiber filters have a pore size of 0.7 microns and are binder free. They are used in Zero-Headspace Extractor Vessels for determining the mobility of semi-volatiles. Filters should be acid washed prior to use with 1N nitric acid followed by three consecutive rinses with deionized water. A minimum of 1 liter per rinse is recommended.
UOM : PK


Add to Quote
filter paper, glass, 934AH, 7cm, 100 pk

FILTER GLASS 934AH PK100 7.0CM

Item #: VAN/28496-911
Supplier #: 28496-911

Cytiva - Whatman 1827-070 Grade 934-AH Glass Microfiber Filter
7cm diameter. For suspended solids in water analysis. Used for harvesting lymphocytes in incorporation trials, mixed lymphocyte culture tests, scintillation counting techniques, air monitoring. Binder free. Fine porosity. Fast flow. 1.5um particle retention. Exact Match 28496-911
UOM : PK


Add to Quote
  • 1
  • 2
  • 3
  • NEXT »

Don't see what you need or would like to request a quotation?

Click here to let us know and we'll help you find what you're looking for!