Viewing Page 1 of 1 (7 results)
Filter 25mm o.45 PTFE/Philic pk/100

Filter 25mm o.45 PTFE/Philic pk/100

Item #: MFS/25HP045AN
Supplier #: 25HP045AN

Advantec MFS Part No. 25HP045AN
3mm, 13mm, 17mm, 25mm, 30mm, 50mm 0.10µm to 5.0µm Minimal sample hold-up High purity, non-pigmented housing and no adhesives used Advantec MFS offers a broad selection of filter media in convenient disposable syringe filters and 50mm in-line filter units. The Acrylic(AC) and Polypropylene(PP) housing materials are high purity and pigment-free. Adhesives are not used so you can be assured filtrates will not be adulterated. Each unit is marked with identifying codes denoting pore size, membrane, and housing polymer. Polypropylene can be autoclaved, acrylic can not. For pre-sterilized units see our sterile listing. Dismic models have female luer-lock inlet and male luer slip outlet. Labodisc-50 models are in-line units with 7-13.5 mm hose barb inlet and outlet connections and an inlet vent. Cellulose Acetate (CA) - Very low protein binding suitable for protein and enzyme solutions. Low aqueous extractables(0.1wt%). Nitrate-free for ground-water samples. Clarify and filter sterilize biological fluids, including buffers and tissue culture solutions. Mixed Cellulose Esters (MCE) - General purpose filtration of aqueous solutions, including clarifying and filter sterilizing biological fluids, buffers, and pharma applications. Offers protein binding. Provides high flow rates. Nylon (NY) - Low extractables, no wetting agents. Nylon offers broad chemical compatibility making it a good choice for HPLC sample prep. Clarify and sterilize aqueous and organic solvent solutions, including buffers and tissue culture solutions. Polytetrafluoroethylene (PTFE) - PTFE is inherently hydrophobic making this media ideal for air filtration and venting applications. Traps aqueous aerosols. Filter organic HPLC samples. PTFE-Hydrophilic - Filter aqueous solutions and organic solvents. This membrane is versatile and and compatible with solvent mixtures used in HPLC, eg. Acetonitrile/Water. PTFE-IC - Use for Ion Chromatography applications. Filter aqueous solutions and organic solvents. Offers the lowest extractables available. (units individually blister packed) Polyvinylidene Fluoride (PVDF) - General purpose filtration of aqueous solutions.Offers low extractables and good chemical compatibility. Filter biological samples and mild organic HPLC solutions. Exhibits low protein binding making it a good choice for protein recovery applications. Please Note: ALL Advantec items have a maximum 48 hour cancellation window. Any cancellations AFTER the 48 hour window will incur a restocking fee equal to the cost of the product.
UOM : PK


Add to Quote
Filter Paper GA55 25mm

Filter Paper GA55 25mm

Item #: MFS/GA5525MM
Supplier #: GA5525MM

Advantec MFS Inc.
Mfg Item # : GA5525MM
Advantec Glass Fiber Depth Filters feature high-loading capacity, fast flow rates, are highly resistant to chemical attack, and biologically inert. General purpose and clarifying filtration grades. Binder-free and thermostable to 500°C. Grade GA55 is a thin filter recommended for clarifying filtration and air pollution monitoring. Nominal Rating 0.6µm Grade GF75 collects very fine particles and has a high collection efficiency at 99.999%(DOP) and slower flow. Ideal for collecting IgG or other very fine protein precipitates. Use for TCLP EPA 1311. Nominal Rating 0.3µm(0.7µm) Grade GB140 is a thick filter with a high loading capacity. Used in industrial waste analysis and for suspended solids. Nominal Rating 0.4µm Grade GC50 is a thin filter recommended as a prefilter for membrane or suspended solids and pollutants in water. Low absorption makes this an ideal filter for scintillation counting. High Collection Efficiency(DOP) of 99.99%. Nominal Rating 0.5µm Grade GD120 has high wet strength and high-loading capacity. Ideal as prefilter for membrane <1.2µm. Nominal Rating 0.9µm Please Note: ALL Advantec items have a maximum 48 hour cancellation window. Any cancellations AFTER the 48 hour window will incur a restocking fee equal to the cost of the product.
UOM : PK


Add to Quote
Filter Glass 0.5M 25MM PK 100

Filter Glass 0.5M 25MM PK 100

Item #: TMS/4749A04
Supplier #: 4749A04

GVS Filter Technology Part No. 1215544
Extend the life of final filters Pore sizes from 0.5 µm to 1.0 µm With or without binders Autoclavable PreSep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Frequency and cost of replacing the final membrane filters is reduced. Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. Maximum operating temperature is 165°C (325°F). Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Not recommended for temperatures exceeding 510°C (950°F). For upstream protection of a membrane within a filter holder, the use of a prefilter that is slightly smaller in diameter than the main filter allows the prefilter to fit inside the O-ring or filter funnel holder seal, ensuring a positive membrane seal. When used as the main filter medium, select a diameter of the same size as the filter holder to be used. Type G15 Glass Fiber Prefilters with Binders (4749A02 to A14) Nominal pore size- 0.5 µm High rentention efficiency Limited dirt-handling capacity Protection of 0.2 µm to 0.8 µm final filters Type G20 Glass Fiber Prefilters with Binders (4749A20 to A32) Nominal pore size- 1.0 µm Surface capture of particles Average retention efficiency Higher dirt-handling capacity Protection of 0.8 µm and larger pore size final filters Type G25 Glass Fiber Prefilters with Binders (4749A40 to A54) Nominal pore size- 1.0 µm Thickness approximately 3.5 times greater than G20 Depth particle capture Average retention efficiency Highest dirt-handling capacity Recommended for solutions with heavy contaminate loads Protection of 0.8 µm and larger pore size final filters Type G40 Glass Fiber Prefilters WITHOUT Binders (4638D60 to D68) Nominal pore size- 1.0 µm Average retention efficiency Highest dirt-handling capacity Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents TCLP Glass Fiber Filters WITHOUT Binders, 0.7 µm Pore Size (4749A72) Borosilicate glass fiber filters designed for use in U.S. EPA Method 1311 Toxicity Characteristic Leaching Procedure (TCLP). Federal regulations require the filters for this application be made of borosilicate glass fiber, contain no binder materials and have an effective pore size of 0.6 to 0.8 microns. GE TCLP glass fiber filters have a pore size of 0.7 microns and are binder free. They are used in Zero-Headspace Extractor Vessels for determining the mobility of semi-volatiles. Filters should be acid washed prior to use with 1N nitric acid followed by three consecutive rinses with deionized water. A minimum of 1 liter per rinse is recommended.
UOM : PK


Add to Quote
Acrodisc Filters 0.45um 25mm

Acrodisc Filters 0.45um 25mm

Item #: VAN/28144-584
Supplier #: 28144-584

Pall Laboratory
Mfg Item # : 4501
Acrodisc* Syringe Filter, 25mm 0.45um. Hydrophobic PTFE membrane for exceptional chemical and temperature compatibility. HPLC certified for low level UV-absorbing extractables. Polypropylene housing. Female Luer-Lok* inlet, standard male slip Luer outlet. 100uL hold-up volume. 1000/pk.
Exact Match: 28144-584
UOM : PK


Add to Quote
ANOTOP 25mm 0.02ul Sterile 50/pl

ANOTOP 25,0.02UM,STERILE PK-50

Item #: WHT/6809-2102
Supplier #: 6809-2102

Cytiva - Whatman 6809-2102 Anotop* 25 Disposable Syringe Filter
0.02um pore size. 25mm diameter. Sterile. Anopore* aluminum oxide membrane with honeycomb pore structure. Compatible with most solvents and aqueous materials. Molded polypropylene housing. Luer lock fittings. For samples up to 100mL. 150uL hold up volume. Exact Match 28138-025
UOM : PK


Add to Quote
MEM FLT 1UM 25MM

WCN WH 25MM 1.0UM PK100

Item #: WHT/7190-002
Supplier #: 7190-002

Cytiva - Whatman 7190-002 Cellulose Nitrate Membranes, circles, plain, 1.0 um 25 mm 100/pk
Recommended for the majority of routine applications, this membrane is manufactured under strictly Controlled conditions. Exact Match 10035-544
UOM : EA


Add to Quote
Glass Fiber Filter 1.0um 25mm pk/1000

Glass Fiber Filter 1.0um 25mm pk/1000

Item #: VAN/34181-092
Supplier #: 34181-092

Pall Laboratory
Mfg Item # : 4529
Glass Fiber Membrane Filter 25mm diameter. 2.8cm2 filtration area. Prefilters aqueous and solvent based samples. 100% binder-free borosilicate glass fiber filter. Low extractables. Polypropylene housing. Female Luer-Lok* inlet. Male slip Luer outlet. 1.0um nominal pore size. 1000/pk.
Exact Match: 34181-092
UOM : PK


Add to Quote

Don't see what you need or would like to request a quotation?

Click here to let us know and we'll help you find what you're looking for!