Browse Categories

Search Filters

  • Filter Paper x

Filter Your Search

Show Attribute Sterility

Browse Categories

Loading...

Search Results

Searching for: {0}
Viewing Page 11 of 19 (187 results)
Nylaflo® Membrane Filter, 0.2 µm, 25mm

Nylaflo® Membrane Filter, 0.2 µm, 25mm

Item #: VAN/28140-028
Supplier #: 28140-028

Pall Laboratory
Mfg Item # : 66601
Nylaflo* Membrane Disc Filter 0.2um pore. 25mm diameter. Hydrophilic nylon filter compatible with esters, bases, alcohols. Not for acids1N or halogenated solvents. Naturally wettable to aqueous solutions. HPLC certified for low levels of UV-absorbing extractables. 100/pk.
Exact Match: 28140-028
UOM : PK


Add to Quote
Filter Paper #1 11um 27.0cm

FILTER PAPER #1 27CM PK100

Item #: WHT/1001-270
Supplier #: 1001-270

Cytiva - Whatman 1001-270 Grade 1 Filter Paper
27.0cm diameter. For a wide range of laboratory applications, liquid clarification, gas filtration, air pollution analysis, and soil analysis. Medium porosity. Medium flow rate. 11um particle retention. Exact Match 28450-207
UOM : PK


Add to Quote
Filter Paper #2 8um 7.0cm

FILTER PAPER #2 7CM PK100

Item #: WHT/1002-070
Supplier #: 1002-070

Cytiva - Whatman 1002-070 Grade 2 Filter Paper
7.0cm diameter. More retentive, slower, and more absorbent than Grade 1 Filter Paper by Whatman*. For general-purpose lab applications, monitoring specific contaminants in the atmosphere, and soil testing. Medium porosity. Medium flow rate. 8um particle retention. Exact Match 28455-063
UOM : PK


Add to Quote
Filter, Nylon Hydrophilic 0.45um, 47mm

MEMB NYL-66 PK100 .45UM 47MM

Item #: WHT/10414112
Supplier #: 10414112

Cytiva - Whatman 10414112 Polyamide Membrane 47mm
Polyamide Membrane, Type: Circle (NL17), pore size: 0.45 um,Diameter: 47mm, Water Flowrate: 20 ml/min/cm2, Maximum Operating Temperature: 135 deg C, suitable for aqueous and organic solutions, mechanically very strong and exhibit excellent wet strength and dry strength Exact Match 28152-899
UOM : PK


Add to Quote
Membrane Filter Nylon 0.45 µm/47mm

FILTER NYLON MEMB 0.45UM PK100

Item #: WHT/7404-004
Supplier #: 7404-004

Cytiva - Whatman 7404-004 Nylon Membrane Filter, Type WNYL
0.45um pore size. 47mm diameter. For biotech and chromatography applications. Intrinsically hydrophilic, eliminating the need for wetting agents. Capable of filtering most organic solvents. Autoclavable. Exact Match 28159-746
UOM : PK


Add to Quote
Filter Paper Quantitative #40 8um 12.5cm

FILTER PAPER 40 PK-100 12.5CM

Item #: WHT/1440-125
Supplier #: 1440-125

Cytiva - Whatman 1440-125 Quantitative Filter Paper 125mm
Quantitative Filter Paper, Grade: 40, Type: circle, Diameter: 125 mm, AirFlow rate: 19.3 s/100 mL/in2, Basis Weight: 95 g/m2, Burst Strength: 0.034 bar wet burst Exact Match 28475-081
UOM : EA


Add to Quote
Filter Paper Black, 3.0cm 100/pk

Filter Paper Black, 3.0cm 100/pk

Item #: ETD/8613-0300
Supplier #: 8613-0300

Ahlstrom 8613 has a smooth black finish designed for use in applications requiring visual examination of particles.•Low ash content 0.06% •Untreated •Consistent performance
UOM : PK


Add to Quote
Glass Fiber Filter 0.7um 47mm pack/100

Glass Fiber Filter 0.7um 47mm pack/100

Item #: TMS/4749A72
Supplier #: 4749A72

GVS Filter Technology Part No. 1215540
Extend the life of final filters Pore sizes from 0.5 µm to 1.0 µm With or without binders Autoclavable PreSep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Frequency and cost of replacing the final membrane filters is reduced. Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. Maximum operating temperature is 165°C (325°F). Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Not recommended for temperatures exceeding 510°C (950°F). For upstream protection of a membrane within a filter holder, the use of a prefilter that is slightly smaller in diameter than the main filter allows the prefilter to fit inside the O-ring or filter funnel holder seal, ensuring a positive membrane seal. When used as the main filter medium, select a diameter of the same size as the filter holder to be used. Type G15 Glass Fiber Prefilters with Binders (4749A02 to A14) Nominal pore size- 0.5 µm High rentention efficiency Limited dirt-handling capacity Protection of 0.2 µm to 0.8 µm final filters Type G20 Glass Fiber Prefilters with Binders (4749A20 to A32) Nominal pore size- 1.0 µm Surface capture of particles Average retention efficiency Higher dirt-handling capacity Protection of 0.8 µm and larger pore size final filters Type G25 Glass Fiber Prefilters with Binders (4749A40 to A54) Nominal pore size- 1.0 µm Thickness approximately 3.5 times greater than G20 Depth particle capture Average retention efficiency Highest dirt-handling capacity Recommended for solutions with heavy contaminate loads Protection of 0.8 µm and larger pore size final filters Type G40 Glass Fiber Prefilters WITHOUT Binders (4638D60 to D68) Nominal pore size- 1.0 µm Average retention efficiency Highest dirt-handling capacity Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents TCLP Glass Fiber Filters WITHOUT Binders, 0.7 µm Pore Size (4749A72) Borosilicate glass fiber filters designed for use in U.S. EPA Method 1311 Toxicity Characteristic Leaching Procedure (TCLP). Federal regulations require the filters for this application be made of borosilicate glass fiber, contain no binder materials and have an effective pore size of 0.6 to 0.8 microns. GE TCLP glass fiber filters have a pore size of 0.7 microns and are binder free. They are used in Zero-Headspace Extractor Vessels for determining the mobility of semi-volatiles. Filters should be acid washed prior to use with 1N nitric acid followed by three consecutive rinses with deionized water. A minimum of 1 liter per rinse is recommended.
UOM : PK


Add to Quote
Filter Paper 0.4um 47mm  100/pack

NUC PC 47MM 0.4UM AOX PK100

Item #: WHT/111137
Supplier #: 111137

Cytiva - Whatman 111137 Nuclepore* Polycarbonate AOX Track-Etched Membranes, Circles, 12.0 uM, 47 mm 100/pk
Manufactured from high-quality polycarbonate film and have sharply defined pore sizes, high flow rates, and excellent chemical and thermal resistance. Exact Match 10034-592
UOM : PK


Add to Quote
ANOTOP 25mm 0.02ul Sterile 50/pl

ANOTOP 25,0.02UM,STERILE PK-50

Item #: WHT/6809-2102
Supplier #: 6809-2102

Cytiva - Whatman 6809-2102 Anotop* 25 Disposable Syringe Filter
0.02um pore size. 25mm diameter. Sterile. Anopore* aluminum oxide membrane with honeycomb pore structure. Compatible with most solvents and aqueous materials. Molded polypropylene housing. Luer lock fittings. For samples up to 100mL. 150uL hold up volume. Exact Match 28138-025
UOM : PK


Add to Quote
  • « PREV
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • NEXT »

Don't see what you need or would like to request a quotation?

Click here to let us know and we'll help you find what you're looking for!

The following web pages were found that match your search

Core Suppliers 2/2/2023
A & D Weighing AAPER Alcohol Ace Glass ACP Chemicals Advantec MFS Advantech Manufacturing Ahlstrom Filtration Air Gas Safety Inc. Ajay North America All-Pak Inc... More
Punchout Features View Inventory View Contract Pricing View Complete Catalog Browse Our Catalog Shop GCU Core Items Using punchouts is simple... 1 2 3 To... More
About Us 5/20/2021
As a distributor of laboratory chemicals instruments and supplies Northwest Scientific has served the scientific needs of customers in North America since 1948 with the... More