Browse Categories

Search Filters

  • Restek Corporation x

Filter Your Search

Browse Categories

Loading...

Search Results

Searching for: {0}
Viewing Page 6 of 10 (96 results)
Residual Solvents Class 2 - Mix A

Residual Solvents Class 2 - Mix A

Item #: RTK/36012
Supplier #: 36012

RESTEK CORP 36012
Calibration standard Residual Solvents Class 2 - Mix A 1ml Calibration standard Residual Solvents Class 2 - Mix A, 15 components, Solvent: In dimethyl sulfoxide, Storage: 0 deg C or colder, Shelf Life: 6 months, Volume: 1 mL/ampule Exact Match: 75835-436
UOM : EA


Add to Quote

Column, 3um, MXT-BAC1, -20 to 240C

Item #: RTK/78001
Supplier #: 78001

RESTEK CORP 78001
MXT* BAC1 Column 3um MXT* BAC1 Column (Silcosteel* treated stainless steel), proprietary Crossbond* phase, Capillary column, Length: 30m, Internal Diameter: 0.53mm, df: 3um, Temperature: -20 to 240 deg C, Application: for blood alcohol analysis, abused inhalant anesthetics, Y-hydroxybutyrate Exact Match: 10851-564
UOM : EA


Add to Quote
Ultra Amino Guard Cartridge, 5um PK/3

Ultra Amino Guard Cartridge, 5um PK/3

Item #: RTK/910750210
Supplier #: 910750210

RESTEK CORP 910750210
Ultra Amino Guard Cartridge 5um Ultra Amino Guard Cartridge, Particle size: 5 um, Spherical, Size: 10 x 4.0 mm, Pore size: 100 Angstrom, Managing High Backpressure, Guard column requires Trident direct guard cartridge system Exact Match: 10840-192
UOM : PK


Add to Quote
Raptor ARC-18 2.7um EXP Guard Cartridge

Raptor ARC-18 2.7um EXP Guard Cartridge

Item #: RTK/9314A0250
Supplier #: 9314A0250

Restek Corporation
Mfg Item # : 9314A0250
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times without expensive UHPLC instrumentation. Designed and intended specifically for use on LC-MS/MS systems, the Raptor ARC-18 column offers a well-balanced retention profile without the drawbacks of using an ordinary C18 in the harsh, acidic mobile phases needed for mass spectrometry (MS). Even after extended use in these low-pH (≤ 2.0) conditions, the sterically protected ARC-18 offers consistent retention, peak shape, and response for charged bases, neutral acids, small polar compounds, and more. For the rapid analysis of large, multiclass assays by LC-MS/MS, the acid-resistant Raptor ARC-18 truly is ahead of the curve. Stationary Phase Category: C18, octadecylsilane (L1) Ligand Type: Sterically protected C18 Particle: 2.7 µm or 5 µm superficially porous silica (SPP or "core-shell") Pore Size: 90 Å Carbon Load: 7% (2.7 µm), 5% (5 µm) End-Cap: no Surface Area: 150 m 2 /g (2.7 µm) or 100 m 2 /g (5 µm) Recommended Usage: pH Range: 1.0–8.0 Maximum Temperature: 80°C Maximum Pressure: 600 bar/8,700 psi (2.7 µm) or 400 bar/5,800 psi (5 µm) Properties: Ideal for high-throughput LC-MS/MS applications with minimal sample preparation. Well-balanced retention profile for better detection and integration of large, multiclass analyte lists. Sterically protected to endure low-pH mobile phases without sacrificing retention or peak quality. Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica. Switch to an ARC-18 when: You are analyzing large, multiclass lists by LC-MS/MS Strongly acidic (pH 1–3) mobile phases are required Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connections—no tools needed Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port Maximum cartridge pressure: 1,034 bar/15,000 psi* (UHPLC), 600 bar/8,700 psi (2.7 μm); 400 bar/5,800 psi (5 μm) * For maximum lifetime, recommended maximum pressure for UHPLC particles is 830 bar/12,000 psi.
Exact Match: 10840-988
UOM : PK


Add to Quote
Raptor ARC-18 2.7um 150 x 4.6mm

Raptor ARC-18 2.7um 150 x 4.6mm

Item #: RTK/9314A65
Supplier #: 9314A65

Restek Corporation
Mfg Item # : 9314A65
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times without expensive UHPLC instrumentation. Designed and intended specifically for use on LC-MS/MS systems, the Raptor ARC-18 column offers a well-balanced retention profile without the drawbacks of using an ordinary C18 in the harsh, acidic mobile phases needed for mass spectrometry (MS). Even after extended use in these low-pH (≤ 2.0) conditions, the sterically protected ARC-18 offers consistent retention, peak shape, and response for charged bases, neutral acids, small polar compounds, and more. For the rapid analysis of large, multiclass assays by LC-MS/MS, the acid-resistant Raptor ARC-18 truly is ahead of the curve. Stationary Phase Category: C18, octadecylsilane (L1) Ligand Type: Sterically protected C18 Particle: 2.7 µm or 5 µm superficially porous silica (SPP or "core-shell") Pore Size: 90 Å Carbon Load: 7% (2.7 µm), 5% (5 µm) End-Cap: no Surface Area: 150 m 2 /g (2.7 µm) or 100 m 2 /g (5 µm) Recommended Usage: pH Range: 1.0–8.0 Maximum Temperature: 80°C Maximum Pressure: 600 bar/8,700 psi (2.7 µm) or 400 bar/5,800 psi (5 µm) Properties: Ideal for high-throughput LC-MS/MS applications with minimal sample preparation. Well-balanced retention profile for better detection and integration of large, multiclass analyte lists. Sterically protected to endure low-pH mobile phases without sacrificing retention or peak quality. Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica. Switch to an ARC-18 when: You are analyzing large, multiclass lists by LC-MS/MS Strongly acidic (pH 1–3) mobile phases are required Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connections—no tools needed Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port Maximum cartridge pressure: 1,034 bar/15,000 psi* (UHPLC), 600 bar/8,700 psi (2.7 μm); 400 bar/5,800 psi (5 μm) * For maximum lifetime, recommended maximum pressure for UHPLC particles is 830 bar/12,000 psi.
Exact Match: 10841-014
UOM : EA


Add to Quote

Column, Raptor C18, 2.7um, 100 x 4.6mm

Item #: RTK/9304A15
Supplier #: 9304A15

Recommended Usage: pH Range: 2.0–8.0 Maximum Temperature: 80 °C Maximum Pressure: 1034 bar/15,000 psi* (1.8 µm), 600 bar/8700 psi (2.7 µm); 400 bar/5800 psi (5 µm)
UOM : EA


Add to Quote
Column RTX-1 Cap

Column RTX-1 Cap

Item #: RTK/10123
Supplier #: 10123

Column, GC; Restek; Product: Rtx-1; Fused silica capillary; Nonpolar phase; Exact Match bond 100% dimethyl polysiloxane; Temp. limit: -60deg. to +330/350deg.C; 30m; I.D.: 0.25mm; Film thickness: 0.25um df; 1/EA Exact Match 6708263 RK10123
UOM : EA


Add to Quote
Dual Column Injection TE

Dual Column Injection TE

Item #: RTK/20411
Supplier #: 20411

Tee, Injection; Restek; Direct; Dual column; Replacement part for dual 0.32 and 0.53mm I.D. Fused silica capillary columns; Designed with glass spiral; Press-Tight taper in each outlet leg; 1/EA Exact Match 6710617 RK20411
UOM : EA


Add to Quote
EZ No Vent Connector Kit

EZ No Vent Connector Kit

Item #: RTK/21323
Supplier #: 21323

Connector Kit, EZ No-Vent, For Agilent 5971, 5972, 5973 GC/MS, Includes: Connector, Two 0.4mm ID ferrules for capillary column, Two 0.4mm ID ferrules for transfer line, 100 Micrometer deactivated transfer line 3 ft., Column plug and nut; 1/EA Exact Match 6711924 RK21323
UOM : EA


Add to Quote
Hydrogen Generator, 850cc/min, 100psi

Hydrogen Generator, 850cc/min, 100psi

Item #: RTK/22148
Supplier #: 22148

Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes. Maintenance-free palladium purifier removes oxygen to <0.01 ppm and moisture to <1.0 ppm. Produces continuous supply of 99.99999+% pure hydrogen gas. Does not require downstream gas filters. Maximum outlet pressures of 100 or 175 psig (690 or 1,200 kPa). Automatic safety feature shuts the generator down if a hydrogen leak is detected. Compact unit, requires only one square foot of bench space. Mfr. No. H2PEMPD-850
UOM : EA


Add to Quote
  • « PREV
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • NEXT »

Don't see what you need or would like to request a quotation?

Click here to let us know and we'll help you find what you're looking for!

The following web pages were found that match your search

Core Suppliers 2/2/2023
A & D Weighing AAPER Alcohol Ace Glass ACP Chemicals Advantec MFS Advantech Manufacturing Ahlstrom Filtration Air Gas Safety Inc. Ajay North America All-Pak Inc... More
Punchout Features View Inventory View Contract Pricing View Complete Catalog Browse Our Catalog Shop GCU Core Items Using punchouts is simple... 1 2 3 To... More
About Us 5/20/2021
As a distributor of laboratory chemicals instruments and supplies Northwest Scientific has served the scientific needs of customers in North America since 1948 with the... More