Search Filters
-
Koehler Instrument Company, Inc. x
Filter Your Search
Category Group
Browse Categories
Loading...
Search Results
COPPER TEST STRIP
Item #:
KOE/K25080
Supplier #: K25080
Supplier #: K25080
Strips, Copper Test; Koehler Instruments; Accessory to be used with Copper Strip Tarnish Test Apparatus; 12.5 x 1.5 to 3.0 x 75mm; Conforms to ASTM specifications; 1/EA Exact Match KLK25080 89399-764
Silicone Plug for Distillation Flask
Item #:
KOE/334-002-001
Supplier #: 334-002-001
Supplier #: 334-002-001
The silicone plug has an opening through the center of it to allow a thermometer to be installed and held by the stopper. The Teflon stopper for our automatic instrument measured 16.1mm at its narrowest point, while the silicone plugs measured.Pack of 10
Pensky-Martens Flash Tester 115v
Item #:
KOE/K16203
Supplier #: K16203
Supplier #: K16203
KOEHLER INSTRUMENT COMPANY Part No. K16203
Test Method For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Pensky-Martens Closed Cup Flash Tester Conforms to ASTM D93 and related specifications Choice of electric or gas heating Determines flash points of a wide range of products by a closed cup method with two option speed stirring of the sample. Extensively used in shipping and safety regulations for detection of contamination by volatile and flammable materials in fuel oils and lubricating oils, and for characterization of hazardous waste samples. Smooth operating cover mechanism slides shutter open and applies test flame at the turn of a knob. Cover fits over brass test cup and includes pilot flame, test flame reference bead, built-in stirrer and plated brass thermometer ferrule. Electrically heated model is equipped with a 1000W nickel-chromium heater with stepless variable control for accurate, repeatable temperature rate of rise settings per specifications. Heater unit is enclosed in a stainless steel housing with cooling vents. Includes line cord receptacle and switch for accessory slow speed stirrer. Gas heated model has a built-in nickel plated brass natural gas burner, or can be supplied with an artificial gas burner or liquid propane burner (specify when ordering). Both models are mounted on a sturdy cast iron base. Included Accessories Brass Test Cup with Handle Thermometer Holder Cover Assembly Specifications Conforms to the specifications of: ASTM D93; AASHTO T73-811; IP 34; ISO 2719; DIN 51758; FTM 791-1102; NF M 07-019 Electrical Requirements: 115V 60Hz, Single Phase, 6.5A 220-240V 50/60Hz, Single Phase, 3.4A Please call Customer Service for pricing on Electrically Heated Models (models K16203 & K16273).
Test Method For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Pensky-Martens Closed Cup Flash Tester Conforms to ASTM D93 and related specifications Choice of electric or gas heating Determines flash points of a wide range of products by a closed cup method with two option speed stirring of the sample. Extensively used in shipping and safety regulations for detection of contamination by volatile and flammable materials in fuel oils and lubricating oils, and for characterization of hazardous waste samples. Smooth operating cover mechanism slides shutter open and applies test flame at the turn of a knob. Cover fits over brass test cup and includes pilot flame, test flame reference bead, built-in stirrer and plated brass thermometer ferrule. Electrically heated model is equipped with a 1000W nickel-chromium heater with stepless variable control for accurate, repeatable temperature rate of rise settings per specifications. Heater unit is enclosed in a stainless steel housing with cooling vents. Includes line cord receptacle and switch for accessory slow speed stirrer. Gas heated model has a built-in nickel plated brass natural gas burner, or can be supplied with an artificial gas burner or liquid propane burner (specify when ordering). Both models are mounted on a sturdy cast iron base. Included Accessories Brass Test Cup with Handle Thermometer Holder Cover Assembly Specifications Conforms to the specifications of: ASTM D93; AASHTO T73-811; IP 34; ISO 2719; DIN 51758; FTM 791-1102; NF M 07-019 Electrical Requirements: 115V 60Hz, Single Phase, 6.5A 220-240V 50/60Hz, Single Phase, 3.4A Please call Customer Service for pricing on Electrically Heated Models (models K16203 & K16273).
Rapid Flash Tester, Aluminum 115V
Item #:
KOE/K16500
Supplier #: K16500
Supplier #: K16500
Open cup models are used for determining sustained burning characteristics of mixtures of flammable and nonflammable liquids or liquids with widely different flash points when assessing flammability characteristics; temperature range is ambient to 100°C (212°F). Closed cup models are used for routine flash point testing in the range of –30 to 300°C (–22 to 572°F). Closed cup testers with an aluminum test cup have a brass lid and shutter; stainless steel test cup testers are furnished with a stainless steel lid and shutter.
Silver Test Strip
Item #:
KOE/K25280
Supplier #: K25280
Supplier #: K25280
KOEHLER INSTRUMENT COMPANY Part No. K25280
Copper Strip Corrosion Test Bomb Conforms to range of standards Precision-machined stainless steel bomb inserts in copper corrosion bath for testing aviation fuels and natural gasoline. Bomb withstands test pressure of 100 psi (689 kPa) per specifications. Threaded cap with O-ring gasket and knurled circumference hand tightens to a positive seal. A 1/8” groove in the bomb threads permit safe, gradual release of pressure when opening the bomb. Device conforms to specifications of ASTM D130, D6074, D6158, IP 154, ISO 2160, DIN 51759, FTM 791-5325 and NF M 07-015. Shipping weight is 2 lbs. Unit tests the corrosiveness of aviation test fuels towards silver. A polished silver strip is immersed in a fuel sample at an elevated temperature. After a specified test period, the strip is removed from the sample, washed and evaluated for corrosion. The fully insulated, thermostatically controlled water bath features a constant water level device. The bath is used in conjunction with the Batch Conversion Kit to immerse six 350 mL test tubes for silver strip corrosion tests. Bath features stainless steel, double-wall construction. Unit conforms to IP 227 specifications.
Copper Strip Corrosion Test Bomb Conforms to range of standards Precision-machined stainless steel bomb inserts in copper corrosion bath for testing aviation fuels and natural gasoline. Bomb withstands test pressure of 100 psi (689 kPa) per specifications. Threaded cap with O-ring gasket and knurled circumference hand tightens to a positive seal. A 1/8” groove in the bomb threads permit safe, gradual release of pressure when opening the bomb. Device conforms to specifications of ASTM D130, D6074, D6158, IP 154, ISO 2160, DIN 51759, FTM 791-5325 and NF M 07-015. Shipping weight is 2 lbs. Unit tests the corrosiveness of aviation test fuels towards silver. A polished silver strip is immersed in a fuel sample at an elevated temperature. After a specified test period, the strip is removed from the sample, washed and evaluated for corrosion. The fully insulated, thermostatically controlled water bath features a constant water level device. The bath is used in conjunction with the Batch Conversion Kit to immerse six 350 mL test tubes for silver strip corrosion tests. Bath features stainless steel, double-wall construction. Unit conforms to IP 227 specifications.
LPG Corrosion Test Cylinder
Item #:
KOE/K40000
Supplier #: K40000
Supplier #: K40000
Cylinder, LPG Copper Strip Corrosion Test; Koehler Instrument; SS made; 0.25 in. needle valves for purging and admitting LPG samples; Dip tube with hook; Knurled, threaded cap with O-ring gasket hand tightens to a positive seal; 1/EA Exact Match KLK40000 52933-560
COPPER TEST STRIP
Item #:
KOE/K40200
Supplier #: K40200
Supplier #: K40200
Strip, Copper; Koehler Instruments; For LPG; 12.5x1.5-3.0x75mm with 3.2mm hole per ASTM specifications; 1/EA Exact Match KLK40200
Powertrol Heater 115V 1250w
Item #:
KOE/K42000
Supplier #: K42000
Supplier #: K42000
Heater, Utility; Koehler Instrument; General-purpose; Precise, reproducible settings; 750W nichrome heater option; Polished SS housing; L x W x H: 12.7 x 12.7 x 25.4cm (5 x 5 x 10 in.); 115V, 50/60Hz, 750W; 1/EA Exact Match 22280434