Search Filters
-
GVS Life Science/FKA Maine Manufacturing x
Filter Your Search
Category Group
Browse Categories
Loading...
Search Results
Microbiological Membrane Filters 0.45um
Item #:
MAI/10497601
Supplier #: 10497601
Supplier #: 10497601
Microbiological Monitor 100ml Sterile Microbiological Monitor with Black Cellulose Nitrate Membrane and White Grid Pore Size 0.45um Diameter 5.6cm Specifically for membrane filter methods for aqueous samples of up to 100mL. Exact Match 10057-610
Syringe Filter, 0.20um, .25mm PP,FLL/MLS
Item #:
GVS/FJ25BNPPE002AD01
Supplier #: FJ25BNPPE002AD01
Supplier #: FJ25BNPPE002AD01
GVS LIFE SCIENCES Part No. FJ25BNPPE002AD01
Increased throughput and speed of sample preparation Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Strict quality control: Syringe filters are integritytested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Accurate labeling: Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging. Modified acrylic housing to bidirectionally support the membrane allowing sample injection or aspiration Features and Benefits Membrane materials: Cellulose Acetate, Nylon, PTFE, PES, PVDF, Regenerated Cellulose, Nitrocellulose, Polyethylene, Glass Fiber Membrane Diameter: 25 mm Pore Size: 0.20 μm, 0.22 μm, 0.45 µm, 0.80 µm, 1.20 µm, 5.00 µm and others Applications HPLC sample preparation Biological fluids Buffer solutions Sterile filtering of tissue culture media Protein aqueous solutions
Increased throughput and speed of sample preparation Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Strict quality control: Syringe filters are integritytested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Accurate labeling: Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging. Modified acrylic housing to bidirectionally support the membrane allowing sample injection or aspiration Features and Benefits Membrane materials: Cellulose Acetate, Nylon, PTFE, PES, PVDF, Regenerated Cellulose, Nitrocellulose, Polyethylene, Glass Fiber Membrane Diameter: 25 mm Pore Size: 0.20 μm, 0.22 μm, 0.45 µm, 0.80 µm, 1.20 µm, 5.00 µm and others Applications HPLC sample preparation Biological fluids Buffer solutions Sterile filtering of tissue culture media Protein aqueous solutions
Syringe Filter, 0.22um 25mm 50/pk
Item #:
GVS/FJ25BSCCA002AL01
Supplier #: FJ25BSCCA002AL01
Supplier #: FJ25BSCCA002AL01
GVS LIFE SCIENCES Part No. FJ25BSCCA002AL01
Increased throughput and speed of sample preparation Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Strict quality control: Syringe filters are integritytested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Accurate labeling: Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging. Modified acrylic housing to bidirectionally support the membrane allowing sample injection or aspiration Features and Benefits Membrane materials: Cellulose Acetate, Nylon, PTFE, PES, PVDF, Regenerated Cellulose, Nitrocellulose, Polyethylene, Glass Fiber Membrane Diameter: 25 mm Pore Size: 0.20 μm, 0.22 μm, 0.45 µm, 0.80 µm, 1.20 µm, 5.00 µm and others Applications HPLC sample preparation Biological fluids Buffer solutions Sterile filtering of tissue culture media Protein aqueous solutions
Increased throughput and speed of sample preparation Lower hold-up volume due to an improved flow channel design and reduced spacing between the supports within the housing for better handling of small sample volumes or costly samples. Strict quality control: Syringe filters are integritytested to ensure a proper filter fit and weld to eliminate any potential filter by-pass. Accurate labeling: Each filter is labeled with the specific filter material and pore size for easy identification even if the syringe filter is not in its original packaging. Modified acrylic housing to bidirectionally support the membrane allowing sample injection or aspiration Features and Benefits Membrane materials: Cellulose Acetate, Nylon, PTFE, PES, PVDF, Regenerated Cellulose, Nitrocellulose, Polyethylene, Glass Fiber Membrane Diameter: 25 mm Pore Size: 0.20 μm, 0.22 μm, 0.45 µm, 0.80 µm, 1.20 µm, 5.00 µm and others Applications HPLC sample preparation Biological fluids Buffer solutions Sterile filtering of tissue culture media Protein aqueous solutions
Black/White Grid Sterile 0.45um 56mm
Item #:
GVS/10497601
Supplier #: 10497601
Supplier #: 10497601
GVS LIFE SCIENCES Part No. 10497601
Microbiological Monitor: The membrane is fixed to the unit. Available 47 mm or 56 mm Features and Benefits: Rapid testing: Pre-sterilized reduces testing time by up to 70% No flaming required: Combined filtration unit minimizes the risk of cross-contamination Filtration unit easily converts to a Petri dish, which can be labeled and incubated for culturing Reproducible results: All-in-one filtration unit reduces the chance of external error Applications: Microbiological analysis of Potable water, Beer and wine, Waste water, Dairy products, Soft drinks, Other Liquid samples. Suited for monitoring contaminants in all types of samples, from raw materials to finished products.
Microbiological Monitor: The membrane is fixed to the unit. Available 47 mm or 56 mm Features and Benefits: Rapid testing: Pre-sterilized reduces testing time by up to 70% No flaming required: Combined filtration unit minimizes the risk of cross-contamination Filtration unit easily converts to a Petri dish, which can be labeled and incubated for culturing Reproducible results: All-in-one filtration unit reduces the chance of external error Applications: Microbiological analysis of Potable water, Beer and wine, Waste water, Dairy products, Soft drinks, Other Liquid samples. Suited for monitoring contaminants in all types of samples, from raw materials to finished products.
Membrane disk, Nylon, 47mm 0.22 µm
Item #:
GVS/1213769
Supplier #: 1213769
Supplier #: 1213769
GVS LIFE SCIENCES Part No. 1213769
Wide chemical compatibility Naturally hydrophilic Wide range of pore sizes Recommended for: aqueous, solvent and mobile phase filtration; HPLC sample penetration and solvent filtration; clarification and sterilization Autoclavable pH range: 3-12 Manufactured using a unique impregnation process that results in a filter with uniform pore sizes and consistent flow rates. The impregnation process also eliminates cracking, breaking and distortion when handled or creased. Each filter has excellent dimensional stability even after autoclaving and is completely unaffected by temperatures up to 180°C (356°F) or steam sterilization. Since Magna Nylon filters are naturally hydrophilic, wetting agents are not used during manufacture. Extractable levels are less than 0.0015 mg/cm 2 . Binding capacity is 350 µg/cm.
Wide chemical compatibility Naturally hydrophilic Wide range of pore sizes Recommended for: aqueous, solvent and mobile phase filtration; HPLC sample penetration and solvent filtration; clarification and sterilization Autoclavable pH range: 3-12 Manufactured using a unique impregnation process that results in a filter with uniform pore sizes and consistent flow rates. The impregnation process also eliminates cracking, breaking and distortion when handled or creased. Each filter has excellent dimensional stability even after autoclaving and is completely unaffected by temperatures up to 180°C (356°F) or steam sterilization. Since Magna Nylon filters are naturally hydrophilic, wetting agents are not used during manufacture. Extractable levels are less than 0.0015 mg/cm 2 . Binding capacity is 350 µg/cm.
Magna™ Nylon Membrane Filter 5.0um 47mm
Item #:
GVS/1213812
Supplier #: 1213812
Supplier #: 1213812
Wide chemical compatibility
•Naturally hydrophilic
•Wide range of pore sizes
•Recommended for: aqueous, solvent and mobile phase filtration; HPLC sample penetration and solvent filtration; clarification and sterilization
•Autoclavable
•pH range: 3-12
Manufactured using a unique impregnation process that results in a filter with uniform pore sizes and consistent flow rates. The impregnation process also eliminates cracking, breaking and distortion when handled or creased. Each filter has excellent dimensional stability even after autoclaving and is completely unaffected by temperatures up to 180°C (356°F) or steam sterilization.
Since Magna Nylon filters are naturally hydrophilic, wetting agents are not used during manufacture. Extractable levels are less than 0.0015 mg/cm2. Binding capacity is 350 µg/cm.