Laboratory Hood, Protector Premier, 5'
Item #:
LCC/10050000034126
Supplier #: 10050000034126
Supplier #: 10050000034126
Left Side: (1) GFCI Duplex, Right Side: (1) GFCI Duplex, Digital Airflow Monitor
Lab Hood 5' w/ Blower 115V
Item #:
LCC/100500040
Supplier #: 100500040
Supplier #: 100500040
Labconco 100500040
Protector Premier By-Pass Hood w/built-in blower capable of 100 fpm exhaust thru max. 75Feet straight duct (duct not included), 5Feet w, 115V. Powder-coated steel exterior. Molded fiberglass liner. Low profile Eco-Foil air foil. 37.5Inch h unobstructed sightline. 12.81Inch ID exhaust collar. Exact Match: 89232-756
Protector Premier By-Pass Hood w/built-in blower capable of 100 fpm exhaust thru max. 75Feet straight duct (duct not included), 5Feet w, 115V. Powder-coated steel exterior. Molded fiberglass liner. Low profile Eco-Foil air foil. 37.5Inch h unobstructed sightline. 12.81Inch ID exhaust collar. Exact Match: 89232-756
Laboratory Hood 6' w/Built in Blower
Item #:
LCC/100600042
Supplier #: 100600042
Supplier #: 100600042
Built in blower, 2 service fixtures and 1 GFCI duplex. 100-115V
Hood, 4' Protector XSteam Lab,
Item #:
LCC/110410000
Supplier #: 110410000
Supplier #: 110410000
Hood, By-Pass; Labconco; Protector XStream; At 60fpm and sash fully open exhausts 430CFM; Powder-coated steel exterior; Composite panel liner; 37.5 in. high unobstructed sightline; Nominal width: 4 ft.; 115V; 1/EA Exact Match 10369100 89232-698
Hood 6' Protector XStream 115V
Item #:
LCC/110610000
Supplier #: 110610000
Supplier #: 110610000
Hood, By-Pass; Labconco; Protector XStream; At 60fpm and sash fully open exhausts 690CFM; Powder-coated steel exterior; Composite panel liner; 37.5 in. high unobstructed sightline; Nominal width: 6 ft.; 115V; 1/EA Exact Match 10369108 89232-714
Protector Xstream Lab Hood 6' 115V
Item #:
LCC/11061000028879
Supplier #: 11061000028879
Supplier #: 11061000028879
6' Xstream with (1) 115V GFCI on left
side and one 115V duplex on the right
side. Digital AFM. Gas and Nitrogen on
right side. Air and CW on left side. With Guardian Air Flow Monitor (9413400)
Protector Xstream Lab Hood, 6 ft.
Item #:
LCC/110610002
Supplier #: 110610002
Supplier #: 110610002
• Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided.
• One pre-wired GFCI electrical duplex receptacle on lower right side.
The Protector XStream Laboratory Hood takes containment, safety and energy savings to the extreme. This general chemical, high performance fume hood was independently tested and challenged well beyond the SEFA-1 standards. With a face velocity of 40 fpm and sash fully open, the Protector XStream was subjected to 50 fpm cross drafts, NIH protocol, and tracer gas measurements in the chest of the mannequin. In all scenarios, the Protector XStream allowed 0.00 ppm average level of tracer gas outside the fume hood. Although your safety officer will determine the actual face velocity setting for your laboratory, the ability of this hood to contain under these adverse conditions sets a new standard of safety.
Safety is foremost, but energy savings is equally impressive. Although face velocity is a factor, it’s the volumetric rate (CFM) that determines the energy consumption. Operating a 6' Protector XStream at 60 fpm face velocity, with the sash in its fully open position, requires only 690 CFM. Regardless of your desired operating face velocity, the Protector XStream yields the lowest required CFM of any hood.
Benchtop Hood 3' Protector XL + GFCI
Item #:
LCC/111300002
Supplier #: 111300002
Supplier #: 111300002
Weight: 350.0 lbs
Weight metric: 159.0 kg
Dimensions: 36.0" w x 31.7" d x 59.0" h
Dimensions metric: 91.4 x 80.5 x 149.9 cm
Electrical: 100-115 volts, 50/60Hz, 10 amps
Product Subcategory: General Chemistry
Nominal Width: 3'
Region: U.S. and Canada, International
Blower Requirements: Remote blower required
Conformance: ANSI Z9.5, ASHRAE 110, ASTM E84, CAN/CSA C22.2, NFPA 45, SEFA 1, UL
Electrical Duplexes: 1
Enclosure Height: 59.0"
Exterior Depth: 31.7" (80.5 cm)
Lighting: T8 fluorescent
Service Fixtures: 2
Style: Benchtop
Benchtop Hood, 3' Wide 31.7" Depth
Item #:
LCC/111300021
Supplier #: 111300021
Supplier #: 111300021
Weight: 350.0 lbs
Weight metric: 159.0 kg
Dimensions: 36.0" w x 31.7" d x 59.0" h
Dimensions metric: 91.4 x 80.5 x 149.9 cm
Electrical: 208-230 volts, 50/60 Hz, 5 amps
Product Subcategory: General Chemistry
Nominal Width: 3'
Region: U.S. and Canada, International
Blower Requirements: Remote blower required
Conformance: ANSI Z9.5, ASHRAE 110, ASTM E84, CAN/CSA C22.2, CE, NFPA 45, SEFA 1, UL
Enclosure Height: 59.0"
Lighting: T8 fluorescent
Service Fixtures: 2
Style: Benchtop